Hide metadata

dc.date.accessioned2013-03-12T09:10:57Z
dc.date.available2013-03-12T09:10:57Z
dc.date.issued2006en_US
dc.date.submitted2006-08-10en_US
dc.identifier.citationPaulsrud, Marit Spidsberg. Synthesis and evaluation of polymer-based monolithic columns in capillary liquid chromatography. Masteroppgave, University of Oslo, 2006en_US
dc.identifier.urihttp://hdl.handle.net/10852/12787
dc.description.abstractAbstract Monolithic poly (styrene-co-divinylbenzene) capillary columns were prepared by free radical cross-linking copolymerisation of styrene and divinylbenzene monomers in the presence of a mixture of tetrahydrofuran (THF) and 1-decanol as porogens inside a fused silica capillary of I.D 180 or 100 μm. The initiator, α,ά-azo-isobutyronitrile was used to initiate the chain reaction. The preparation of the monolithic column was carried out in three steps, pre-treatment, silanization and polymerisation according to a procedure described in the literature. The polymerization step was reinvestigated to get control over the production parameters. To obtain repeatable monolithic columns the amount of chemicals were weighed, and degassing of the polymerization solution with helium had to be avoided to prevent loss of chemicals. Parameters varied were the amount of 1-decanol, THF and divinylbenzene. The composition of the polymerization solution fond to be the best was as follows: 0.911 g divinylbenzene, 0.906 g styrene, 2.371 g 1-decanol, 0.356 g tetrahydrofuran and 40.0 mg (8 mg/ml) α,ά-azo-isobutyronitrile. The amount of 1-decanol was increased with 10%, relative to the amount described in the literature. The amount of the other chemicals in the polymerization solution was unchanged. By using this polymerization solution, columns which were repeatable with respect to efficiency and retention of proteins were produced. Efficiency testing of the columns was performed using a simple mixture of proteins, a mixture of cytochrome c, lysozyme and myoglobin (0.25 mg/mL of each).nor
dc.language.isoengen_US
dc.subjectmonolittiske kolonneren_US
dc.titleSynthesis and evaluation of polymer-based monolithic columns in capillary liquid chromatographyen_US
dc.typeMaster thesisen_US
dc.date.updated2006-08-30en_US
dc.creator.authorPaulsrud, Marit Spidsbergen_US
dc.subject.nsiVDP::440en_US
dc.identifier.bibliographiccitationinfo:ofi/fmt:kev:mtx:ctx&ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:dissertation&rft.au=Paulsrud, Marit Spidsberg&rft.title=Synthesis and evaluation of polymer-based monolithic columns in capillary liquid chromatography&rft.inst=University of Oslo&rft.date=2006&rft.degree=Masteroppgaveen_US
dc.identifier.urnURN:NBN:no-12877en_US
dc.type.documentMasteroppgaveen_US
dc.identifier.duo43189en_US
dc.contributor.supervisorProfessor Elsa Lundanes, Professor Tyge Greibrokken_US
dc.identifier.bibsys060845074en_US


Files in this item

FilesSizeFormatView

No file.

Appears in the following Collection

Hide metadata